  adc300 series vdc vdc % typ. % max. adc301 3.3 73 11 adc302 5 76 11 adc303 12 80 7 adc304 15 80 7 adc305 5 77 10 adc306 12 79 7 ADC307 15 79 7 adc311 3.3 74 8 adc312 5 78 8 adc313 12 82 5 adc314 15 83 5 adc315 5 79 8 adc316 12 82 5 adc317 15 82 5 adc321 3.3 74 8 adc322 5 77 8 adc323 12 81 5 adc324 15 82 5 adc325 5 79 8 adc326 12 81 5 adc327 15 82 5 pin singles duals 1 +vin +vin 2 -vin -vin 4 -vout -vout 5 no pin common 6 +vout +vout tolerance millimeters inches x.x0.25 x.xx0.01 x.xx0.13 x.xxx0.005 pin 0.05 0.002 2463 208th street, ste. 205 http://www.mpsind.com torrance, ca 90501 e-mail: sales@mpsind.com key features selection guide model number input voltage output voltage efficiency load regulation output current 500 400 165 66 500 165 83 133 200 tel: (310) 533-1455 fax: (310) 533-1853 weight ? non-conductive black plastic mechanical dimensions 2.7g (0.10oz) 5 (4.5 ? 5.5) 12 (10.8 ? 13.2) 2w, miniature sip, single & dual output dc/dc converters 19.5x7.6x10.2mm (0.77x0.30x0.40inch) case material ? 400 ma mps industries adc300 dc/dc's are specially designed to provide higher power to 2w in a miniature sip package. the series consists of 21 models with input voltages of 5v, 12v and 24vdc which offers standard output voltages of 3.3v, 5v, 12v, 15v, 5v, 12v and 15vdc for a wide choice. the adc300 series is an excellent selection for a variety of applications including distributed power systems, mixed analog/digital subsystems, portable test equipments, local power networks and battery backed systems. case size ? pin connections 83 66 500 400 ? efficiency up to 83% ? 1000vdc isolation ? mtbf > 2,000,000 hours ? low cost ? input 5, 12 and 24vdc ? output 3.3, 5, 12, 15, 5, 12 and 15vdc ? temperature performance -40c to +85c ? ul 94v-0 package material ? internal smd construction ? industry standard pinout 165 133 200 83 66 24 (21.6 ? 26.4) 133 200 19.5 [0.77] 1 0 . 2 [ 0 . 4 0 ] 3 . 2 [ 0 . 1 3 ] 0 . 5 [ 0 . 0 2 ] 2.3 [0.09] 1 . 3 [ 0 . 0 5 ] 18.5 [0.73] 12 456 7 . 6 [ 0 . 3 0 ] 2.54 [0.100] 0 . 2 5 [ 0 . 0 1 0 ] 0.50 [0.020]
adc300 series min. max. units parameter min. typ. max. units 5vdc input models -0.7 9 vdc isolation voltage 1000 --- --- vdc 12vdc input models -0.7 18 vdc isolation resistance 1000 --- --- m ? 24vdc input models -0.7 30 vdc isolation capacitance --- 80 120 pf --- 260 c switching frequency 50 80 100 khz --- 650 mw parameter conditions min. max. units parameter min. typ. max. units operating temperature ambient -40 85 c line regulation --- 1.2 1.5 % operating temperature case -40 90 c load regulation % storage temperature -40 125 c ripple & noise --- 100 150 mv p-p humidity --- 95 % short circuit cooling units uf 2463 208th street, ste. 205 http://www.mpsind.com torrance, ca 90501 e-mail: sales@mpsind.com 470 390 derating curve 500vdc mtbf 2 maximum capacitive load mil-hdbk-217f @25c ground benign conditions for vin change of 1% io = 20% to 100% --- general characteristics input surge voltage (1000ms) lead temperature (1.5mm from case for 10sec.) 2w, miniature sip, single & dual output dc/dc converters absolute maximum ratings parameter conditions 100khz, 1v 60 seconds --- mhrs environmental characteristics free-air convection output characteristics see selection guide 0.5 second max. internal power dissipation 20mhz bw exceeding the unit absolute maximum ratings could cause damage. these are not continuous operating ratings. tel: (310) 533-1455 fax: (310) 533-1853 models by output voltage (each output on duals) notes: 1. specifications typical at ta=+25c, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. these power converters require a minimum output load to maintain specified regulation. 3. operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 4. all dc/dc converters should be externally fused at the front end for protection. 5. other input and output voltage may be available, please contact factory. 6. all specifications subject to change without notice. 7. for detailed data sheet, please contact us. singles duals ?? ] ambient temperature output power (%) 0 20 40 60 80 100 -40 50 60 80 100 110 90 70 400lfm 200lfm 100lfm natural convection


▲Up To Search▲   

 
Price & Availability of ADC307

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X